Import QC Stations from CSV
Set up many QC stations at once from a CSV, instead of adding cameras and stations one by one.
The import:
- finds each camera on the network by its MAC address
- adds the cameras to the running NVR, without restarting it
- creates the stations with default zones
- applies the default camera configuration to Hanwha cameras: the latest configuration saved to the app for that station type and side, or the built-in one if none was saved
Before you start
- Cameras are mounted, powered and connected to the camera network.
- Cameras already have a username and password set (the ones you put in the CSV).
- You have the right permissions:
quality.settings:writeandadmin.cameras:write.
1. Fill in the sheet
Ask engineering for the QC Station Import Google Sheet template and make a copy for the site. You can also download a CSV template from the import dialog.
- One row per camera. Fill in the station name and type on the station's first camera row. On the next rows of the same station, leave Station Name empty: those rows belong to the station above. Repeating the name works too.
- Use the dropdowns. Hover a column header to see the allowed values.
- Scan MAC addresses from the camera box labels where possible.
- Run Arvist → Validate sheet, fix anything highlighted, then Arvist → Download CSV.
| Station type | Camera sides |
|---|---|
| Turntable | all (one camera only) |
| Stationary | front_low, front_high, back, left_low, left_high, right_low, right_high, top |
| Conveyor belt | front, right, back, left, top |
| Packing table | top_inspection (main), top_evidence (additional) |
| Dock door | left_low, left_high, right_low, right_high, top, front |
| Drive-through | Dock door sides, plus left and right |
Every station needs at least one main camera, at most six.
2. Import
- Go to QC Stations → Setup and click Import CSV.
- Choose the CSV file. The preview lists the stations and cameras it found:
- Errors (red) must be fixed in the sheet and the file uploaded again.
- Warnings (amber) don't stop the import. For example, a non-Hanwha camera won't be auto-configured, or a side without a default zone uses the full frame.
- Pick the camera network interface. If the camera network was set up in Plug & Play, it's selected for you.
- Click Start import and keep the tab open. The progress list shows each step:
- Finding cameras on the network (e.g. 9/11 found)
- Adding cameras to NVR
- Creating station Dock 1 → Applying zones → Configuring Left Low camera, …
- The summary shows what was created. Use Retry for any camera whose configuration failed.
After the import
- Assign an inspection configuration to each new station from the station list, as for manually created stations.
- Check the zones in each station's settings. They start from a default per station type and side; adjust them if the camera view differs.
Troubleshooting
| Message | What to do |
|---|---|
| Not found on the network: Top (00:09:18:…) | Check the camera is powered and cabled to the camera network, and that the MAC in the sheet is correct. The rest of the stations still import. |
| A station with this name already exists | Edit that station from its settings page, or remove its rows from the CSV. |
| MAC … is already used by camera … in another station | The camera is assigned elsewhere. Remove it from that station first, or fix the MAC. |
| A camera is already named "…", which Frigate won't allow as this station's zone name | Usually a camera left over from an earlier import of the same station. Delete that camera, or rename the station in the CSV. |
| Configuring … camera failed | Check the camera's username/password, then click Retry in the summary. |